The combined application of electromagnetic navigation and porcine fibrin sealant in microwave ablation of lung tumors

电磁导航与猪纤维蛋白密封剂联合应用于微波消融肺肿瘤

阅读:1

Abstract

PURPOSE: This retrospective study aims to assess the efficacy of the combined application of electromagnetic navigation (EMN) and porcine fibrin sealant (PFS) in the microwave ablation (MWA) treatment of lung tumors. MATERIAL AND METHODS: In our department from January 2022 to August 2023, 73 patients underwent MWA under standard computed tomography (CT) guidance (CT group) or CT guidance with additional application of EMN and PFS (CT-EMN-PFS group), respectively. The basic data of patients were recorded and analyzed using the Student's t-test and Chi-square test between the two groups, and single factor and multi-factors binary logistic regression analyses were conducted to determine the risk factors of pneumothorax; meanwhile the incidence of complications, the number of CT scans and dose length product (DLP) were calculated and compared between the two guidance modes. RESULTS: Forty-seven patients underwent standard CT-guided MWA, meanwhile the remaining 26 patients underwent CT-guided MWA with combined application of EMN and PFS. The patients with lesions close to the bronchi or interlobar fissures, and underlying emphysema had a higher risk of pneumothorax, the corresponding odds ratio (OR) was 23.290 (p = 0.004), 33.300 (p = 0.019), and 8.007 (p = 0.012), respectively; the combined use of EMN and PFS could reduce the incidence of pneumothorax, with an OR of 0.094 (95 % confidence interval [CI]: 0.015-0.602, p = 0.013). The incidence rates of pneumothorax, pneumorrhagia and pleural effusion were 59.57 %, 61.70 %, and 19.15 % respectively in the CT group, and 30.77 %, 50.00 % and 7.69 % respectively in the CT-EMN-PFS group. The incidence rate of pneumothorax in the CT-EMN-PFS group was significantly lower than that in the CT group (p = 0.017). The median number of CT scans was 9 in the CT group and 5 in the CT-EMN-PFS group, respectively, meanwhile the median DLP was 1060.69 mGy*cm in the CT group and 600.04 mGy*cm in the CT-EMN-PFS group, respectively, which indicated there was a statistical difference in the amount of radiation exposure between the two groups (p < 0.001). CONCLUSION: The combined application of EMN and PFS demonstrates for the first time that there is a lower incidence rate of pneumothorax and significantly less radiation exposure during the MWA of the lung tumors.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。