Model based care in the ICU: A review of potential combined cardio-pulmonary models

重症监护室中的模型化护理:心肺联合模型的潜在应用综述

阅读:1

Abstract

Positive end-expiratory pressure results in a sustained positive intrathoracic pressure, which exerts pressure on intrathoracic vessels, resulting in cardiopulmonary interactions. This sustained positive intrathoracic pressure is known to decrease cardiac preload, and thus, decrease venous return, ultimately reducing both the stroke volume and stressed blood volume of the cardiovascular system. Currently, cardiovascular and pulmonary care are provided independently of one another. That positive end-expiratory pressure alters both stroke volume and stressed blood volume suggests both the pulmonary and cardiovascular state should be conjointly optimised. Optimising these systems in isolation may benefit one system, but have highly detrimental effects on the other. A combined cardiopulmonary model has the potential to provide a better understanding of patient specific pulmonary and cardiovascular state, as well as resulting cardiopulmonary interactions. This would enable simultaneous optimisation of all cardiovascular and pulmonary parameters. Cardiopulmonary interactions are highly patient specific and unpredictable, making accurate modelling of these interactions challenging. A previously validated cardiopulmonary model was found to have increasing errors at high positive end-expiratory pressures. A new iteration, the alpha model, was introduced to resolve this issue. This paper aims to review the alpha model against its predecessors, the previous cardiopulmonary model, and the original three chamber cardiovascular system model. All models are used to identify cardiovascular system parameters from measurements of 4 pigs during a preload reduction manoeuvre. Outputs and parameter estimations from models are compared to assess the relative performance of the alpha model against its predecessors. The novel alpha model was able to reduce model errors under high positive end-expiratory pressure, resulting in more accurate model outputs. At high positive end-expiratory pressures (20cmH2O), the alpha model had an average error of 11.24%, while the original cardiopulmonary model had a much higher error of 52.21%. Furthermore, identified outputs of the alpha model more closely matched those of the 3 chamber model than the previous cardiopulmonary model. On average, at high positive end-expiratory levels, identified model parameters from the alpha model showed a 6.21% difference to those of the 3 chamber model, while the cardiopulmonary model displayed a 39.43% difference. The alpha model proved to be more stable than the original cardiopulmonary model, making it a good candidate for model based care. However, it produced similar parameter outputs to the simpler three chamber cardiovascular model, bringing into question whether the additional complexity is justified, especially considering the low availability of clinical data in the ICU. There is a critical need for model based care to guide important procedures in ICU, such as fluid therapy. Candidate models should be continuously reviewed in order to guarantee the best possible care.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。