Proportional myoelectric control of a virtual bionic arm in participants with hemiparesis, muscle spasticity, and impaired range of motion

对患有偏瘫、肌肉痉挛和活动范围受限的参与者进行虚拟仿生手臂的比例肌电控制

阅读:1

Abstract

BACKGROUND: This research aims to improve the control of assistive devices for individuals with hemiparesis after stroke by providing intuitive and proportional motor control. Stroke is the leading cause of disability in the United States, with 80% of stroke-related disability coming in the form of hemiparesis, presented as weakness or paresis on half of the body. Current assistive exoskeletonscontrolled via electromyography do not allow for fine force regulation. Current control strategies provide only binary, all-or-nothing control based on a linear threshold of muscle activity. METHODS: In this study, we demonstrate the ability of participants with hemiparesis to finely regulate their muscle activity to proportionally control the position of a virtual bionic arm. Ten stroke survivors and ten healthy, aged-matched controls completed a target-touching task with the virtual bionic arm. We compared the signal-to-noise ratio (SNR) of the recorded electromyography (EMG) signals used to train the control algorithms and the task performance using root mean square error, percent time in target, and maximum hold time within the target window. Additionally, we looked at the correlation between EMG SNR, task performance, and clinical spasticity scores. RESULTS: All stroke survivors were able to achieve proportional EMG control despite limited or no physical movement (i.e., modified Ashworth scale of 3). EMG SNR was significantly lower for the paretic arm than the contralateral nonparetic arm and healthy control arms, but proportional EMG control was similar across conditions for hand grasp. In contrast, proportional EMG control for hand extension was significantly worse for paretic arms than healthy control arms. The participants' age, time since their stroke, clinical spasticity rate, and history of botulinum toxin injections had no impact on proportional EMG control. CONCLUSIONS: It is possible to provide proportional EMG control of assistive devices from a stroke survivor's paretic arm. Importantly, information regulating fine force output is still present in muscle activity, even in extreme cases of spasticity where there is no visible movement. Future work should incorporate proportional EMG control into upper-limb exoskeletons to enhance the dexterity of stroke survivors.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。