Endovascular Salvage of Iliac Limb Maldeployment during EVAR Using a CODA Balloon and Bridging Stent: A Case Report

使用 CODA 球囊和桥接支架进行 EVAR 术中髂动脉肢体畸形血管内挽救:病例报告

阅读:1

Abstract

Iliac limb maldeployment during endovascular aneurysm repair (EVAR) is an uncommon but technically challenging complication. In this study, we present a case involving a patient with multiple comorbidities, including hypertension, hyperlipidemia, and coronary artery disease, who underwent EVAR for a progressively enlarging abdominal aortic aneurysm using the ALTO endograft. During the procedure, the right iliac limb was inadvertently deployed outside the contralateral gate into the aneurysm sac, resulting in maldeployment. This complication was successfully managed with endovascular salvage using a CODA balloon and a bridging stent graft. This case illustrates a variation of endovascular correction strategy adapted to the ALTO platform.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。