Decoding Angiotensin Receptors: TOMAHAQ-Based Detection and Quantification of Angiotensin Type-1 and Type-2 Receptors

解码血管紧张素受体:基于TOMAHAQ的血管紧张素1型和2型受体的检测和定量

阅读:9
作者:Caglar Cosarderelioglu, Simion Kreimer, Alma I Plaza-Rodriguez, Pablo A Iglesias, C Conover Talbot Jr, Helmy M Siragy, Robert M Carey, Ceereena Ubaida-Mohien, Brian O'Rourke, Luigi Ferrucci, David A Bennett, Jeremy Walston, Peter Abadir

Abstract

Background The renin-angiotensin system plays a crucial role in human physiology, and its main hormone, angiotensin, activates 2 G-protein-coupled receptors, the angiotensin type-1 and type-2 receptors, in almost every organ. However, controversy exists about the location, distribution, and expression levels of these receptors. Concerns have been raised over the low sensitivity, low specificity, and large variability between lots of commercially available antibodies for angiotensin type-1 and type-2 receptors, which makes it difficult to reconciliate results of different studies. Here, we describe the first non-antibody-based sensitive and specific targeted quantitative mass spectrometry assay for angiotensin receptors. Methods and Results Using a technique that allows targeted analysis of multiple peptides across multiple samples in a single mass spectrometry analysis, known as TOMAHAQ (triggered by offset, multiplexed, accurate mass, high resolution, and absolute quantification), we have identified and validated specific human tryptic peptides that permit identification and quantification of angiotensin type-1 and type-2 receptors in biological samples. Several peptide sequences are conserved in rodents, making these mass spectrometry assays amenable to both preclinical and clinical studies. We have used this method to quantify angiotensin type-1 and type-2 receptors in postmortem frontal cortex samples of older adults (n=28) with Alzheimer dementia. We correlated levels of angiotensin receptors to biomarkers classically linked to renin-angiotensin system activation, including oxidative stress, inflammation, amyloid-β load, and paired helical filament-tau tangle burden. Conclusions These robust high-throughput assays will not only catalyze novel mechanistic studies in the angiotensin research field but may also help to identify patients with an unbalanced angiotensin receptor distribution who would benefit from angiotensin receptor blocker treatment.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。