Methods

Cervicovaginal swabs (CVS) were prepared by submerging flocked swabs in efavirenz-spiked plasma matrix. Time to full saturation, weight uniformity, recovery and room temperature stability were evaluated. Chromatographic separation was on a reverse-phase C18 column by gradient elution using 1mM ammonium acetate in water/acetonitrile at 400 µL/min. Detection and quantification were on a TSQ Quantum Access triple quadrupole mass spectrometer operated in negative ionisation mode. The method was used to quantify efavirenz in CVS samples from human immunodeficiency virus (HIV)-positive women in the VADICT study (NCT03284645). A total of 98 samples (35 paired intensive CVS and DBS pharmacokinetic samples, 14 paired sparse CVS and DBS samples) from 19 participants were available for this analysis.

Results

Swabs were fully saturated within 15 seconds, absorbing 128 µL of plasma matrix with coefficient of variation (%CV) below 1.3%. The method was linear with a weighting factor (1/X) in the range of 25-10000 ng/mL with inter- and intra-day precision (% CV) of 7.69-14.9%, and accuracy (% bias) of 99.1-105.3%. Mean recovery of efavirenz from CVS was 83.8% (%CV, 11.2) with no significant matrix effect. Efavirenz remained stable in swabs for at least 35 days after drying and storage at room temperature. Median (range) CVS efavirenz AUC 0-24h was 16370 ng*h/mL (5803-22088), C max was 1618 ng/mL (610-2438) at a T max of 8.0 h (8.0-12), and C min was 399 ng/mL (110-981). Efavirenz CVS:plasma AUC 0-24h ratio was 0.41 (0.20-0.59). Conclusions: Further application of this method will improve our understanding of the pharmacology of other therapeutics in the female genital tract, including in low- and middle-income countries.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。