Assessment of the relationship between signal intensities and transcript concentration for Affymetrix GeneChip arrays

Affymetrix GeneChip 阵列信号强度与转录本浓度之间关系的评估

阅读:3
作者:Eugene Chudin, Randal Walker, Alan Kosaka, Sue X Wu, Douglas Rabert, Thomas K Chang, Dirk E Kreder

Background

Affymetrix microarrays have become increasingly popular in gene-expression studies; however, limitations of the technology have not been well established for commercially available arrays. The hybridization signal has been shown to be proportional to actual transcript concentration for specialized arrays containing hundreds of distinct probe pairs per gene. Additionally, the technology has been described as capable of distinguishing concentration levels within a factor of 2, and of detecting transcript frequencies as low as 1 in 2,000,000. Using commercially available arrays, we assessed these representations directly through a series of 'spike-in' hybridizations involving four prokaryotic transcripts in the absence and presence of fixed eukaryotic background. The contribution of probe-target interactions to the mismatch signal was quantified under various analyte concentrations.

Conclusions

Landmark studies outlining an observed linear relationship between signal and transcript concentration were carried out under highly specialized conditions and may not extend to commercially available arrays under routine operating conditions. Additionally, alternative metrics that are not based on the difference in the signal of members of a probe pair may further improve the quantitative utility of the Affymetrix GeneChip array.

Results

A linear relationship between transcript abundance and signal was consistently observed between 1 pM and 10 pM transcripts. The signal ceased to be linear above the 10 pM level and commenced saturating around the 100 pM level. The 0.1 pM transcripts were virtually undetectable in the presence of eukaryotic background. Our measurements show that preponderance of the signal for mismatch probes derives from interactions with the target transcripts. Conclusions: Landmark studies outlining an observed linear relationship between signal and transcript concentration were carried out under highly specialized conditions and may not extend to commercially available arrays under routine operating conditions. Additionally, alternative metrics that are not based on the difference in the signal of members of a probe pair may further improve the quantitative utility of the Affymetrix GeneChip array.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。