Antibacterial coating of orthodontic elastomeric ligatures with silver and bismuth nanofilms by magnetron sputtering: A feasibility study

磁控溅射银和铋纳米薄膜对正畸弹性结扎线进行抗菌涂层的可行性研究

阅读:14
作者:Andrea Schubert, Carolin Griesmüller, Nikolaus Gersdorff, Ralf Bürgers, Bernhard Wiechens, Torsten Wassmann

Conclusions

Magnetron sputtering proved to be a feasible method to equip orthodontic elastomeric ligatures with silver and bismuth nanofilms. Silver coatings of elastomeric ligatures may reduce white spots and carious lesions in orthodontic patients. Future research is required to stabilize coatings.

Material and methods

Antibacterial properties were evaluated by the adhesion of Streptococcus mutans. Polyurethane-based elastomeric ligatures were coated with silver and bismuth nanofilms via direct current magnetron sputtering. Surface roughness (Ra ) and surface-free energy (SFE) were assessed. Coated specimens were incubated with S. mutans for 2 h. Adhering bacteria were visualized by Hoechst staining and quantified by an ATP-based luminescence assay. One-way analysis of variance with Tukey post hoc testing and Pearson correlation analysis were performed (p < .05) to relate bacterial adhesion to surface roughness and surface-free energy.

Methods

Antibacterial properties were evaluated by the adhesion of Streptococcus mutans. Polyurethane-based elastomeric ligatures were coated with silver and bismuth nanofilms via direct current magnetron sputtering. Surface roughness (Ra ) and surface-free energy (SFE) were assessed. Coated specimens were incubated with S. mutans for 2 h. Adhering bacteria were visualized by Hoechst staining and quantified by an ATP-based luminescence assay. One-way analysis of variance with Tukey post hoc testing and Pearson correlation analysis were performed (p < .05) to relate bacterial adhesion to surface roughness and surface-free energy.

Results

Elastomeric ligatures were successfully coated with silver and bismuth nanofilms. Ra was significantly reduced by silver coating. Silver and bismuth coatings showed significantly higher SFE than controls. Adhesion of S. mutans was significantly decreased by silver coating. No correlation between bacterial adhesion and SFE was found. Correlation between bacterial adhesion and Ra was positive but not statistically significant. Conclusions: Magnetron sputtering proved to be a feasible method to equip orthodontic elastomeric ligatures with silver and bismuth nanofilms. Silver coatings of elastomeric ligatures may reduce white spots and carious lesions in orthodontic patients. Future research is required to stabilize coatings.