Variability in telavancin cross-reactivity among vancomycin immunoassays

万古霉素免疫测定中特拉万星交叉反应的差异

阅读:13
作者:Kevin W McConeghy, Siyun Liao, Douglas Clark, Philip Worboys, Steven L Barriere, Keith A Rodvold

Abstract

Telavancin is a semisynthetic lipoglycopeptide with a dual mechanism of action against Gram-positive pathogens. Two brief reports have suggested potential cross-reactivity of telavancin with the vancomycin particle-enhanced turbidometric immunoassay (PETIA). The purpose of this study was to evaluate several commercially available vancomycin immunoassays (fluorescence polarization [FPIA], enzyme-multiplied immunoassays [EMIT], PETIA, and chemiluminescent immunoassay [CMIA]) for cross-reactivity with telavancin. Seven sites were selected to analyze serum samples for vancomycin. Each site received a set of samples (n = 18) which combined drug-free serum with telavancin, 7-OH telavancin metabolite, or vancomycin. Immunoassays demonstrating potential cross-reactivity were further evaluated by sending a duplicate sample set to multiple laboratories. Cross-reactivity was defined as the percent theoretical concentration (reported concentration/theoretical concentration × 100). No cross-reactivity was seen with FPIA or EMIT. Within the theoretical concentration range of 5 to 120 μg/ml of telavancin, the Synchron PETIA system reported vancomycin concentrations ranging from 4.7 to 54.2 μg/ml compared to vancomycin concentrations from 1.1 to 5.6 μg/ml for the Vista PETIA system. The Architect CMIA system reported vancomycin concentrations in the range of 0.27 to 0.97 μg/ml, whereas Advia Centaur XP CMIA reported vancomycin concentrations between 1.6 and 31.6 μg/ml. The Architect CMIA immunoassay had the lowest percent cross-reactivity (0.8 to 5.4%), while the Synchron PETIA immunoassay demonstrated the highest percent cross-reactivity (45.2 to 53.8%). Telavancin samples measured by liquid chromatography-mass spectroscopy were within 93.9 to 122% of theoretical concentrations. Vancomycin concentrations were not measured in any 7-OH telavancin-spiked sample. Vancomycin concentrations measured by liquid chromatography-mass spectroscopy were within 57.2 to 113% of theoretical concentrations. PETIA and CMIA measured vancomycin concentrations in telavancin-spiked samples. Significant variability in percent cross-reactivity was observed for each platform regardless of immunoassay method.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。