Standardized evaluation of Zika nucleic acid tests used in clinical settings and blood screening

寨卡病毒核酸检测在临床及血液筛查中的标准化评估

阅读:5
作者:Mars Stone, Sonia Bakkour, Eduard Grebe, Devy M Emperador, Camille Escadafal, Xutao Deng, Honey Dave, Cassandra Kelly-Cirino, Eve Lackritz, Diana P Rojas, Graham Simmons, Ingrid B Rabe, Michael P Busch

Abstract

Early detection of Zika virus (ZIKV) transmission within geographic regions informs implementation of community mitigation measures such as vector reduction strategies, travel advisories, enhanced surveillance among pregnant women, and possible implementation of blood and organ donor screening or deferral. Standardized, comparative assessments of ZIKV assay and testing lab performance are important to develop optimal approaches to ZIKV diagnostic testing and surveillance. We conducted an expanded blinded panel study to characterize and compare the analytical performance of fifteen diagnostic and blood screening ZIKV NAT assays, including detection among single- and multiplex assays detecting ZIKV, dengue virus (DENV) and chikungunya virus (CHIKV). A 300 member blinded panel was constructed, consisting of 11 serial half-log dilutions ranging from ~104 to 10-1 genome equivalents/mL in 25 replicates each of the Tahitian Asian ZIKV isolate in ZIKV-negative human serum. Additionally, clinical samples from individuals with DENV-like syndrome or suspected ZIKV infection in Brazil were evaluated. The majority of assays demonstrated good specificity. Analytical sensitivities varied 1-2 logs, with a substantially higher limit of detection (LOD) in one outlier. Similar analytical sensitivity for ZIKV RNA detection in singleplex and multiplex assays of the Grifols and ThermoFisher tests were observed. Coefficient of Assay Efficiency (CE), calculated to characterize assays' RNA extraction and amplification efficiency, ranged from 0.13 for the Certest VIASURE multiplex and 0.75 for the Grifols multiplex assays. In general, assays using transcription mediated amplification (TMA) technology had greater CE compared to assays using conventional PCR technology. Donor screening NAT assays were significantly more sensitive than diagnostic RT-qPCR assays, primarily attributable to higher sample input volumes. However, ideal assays to maximize sensitivity and throughput may not be a viable option in all contexts, with other factors such as cost, instrumentation, and regulatory approval status influencing assay availability and selection, particularly in resource constrained settings.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。