Heparin coating in biodegradable ureteral stents does not decrease bacterial colonization-assessment in ureteral stricture endourological treatment in animal model

可生物降解输尿管支架中的肝素涂层不会降低动物模型中输尿管狭窄腔内泌尿治疗中的细菌定植评估

阅读:6
作者:Federico Soria, Julia E de La Cruz, Tomás Fernandez, Alberto Budia, Álvaro Serrano, Francisco M Sanchez-Margallo

Background

We assessed an antireflux biodegradable heparin-coated ureteral stent (BraidStent®-H) in an animal model comparative study after endoscopic treatment of ureteral strictures.

Conclusions

BraidStent®-H has been shown to be as efficacious as current ureteral stents in the treatment of benign ureteral strictures following laser endoureterotomy. In addition, it reduces the morbidity associated with current stents and has a homogeneous and predictable degradation rate of about 6 weeks, with no obstructive fragments. Future studies are required to improve the antibacterial coating to reduce BraidStent®-H contamination in view of the results obtained with the heparin coating.

Methods

A total of 24 female pigs underwent initial endoscopic, nephrosonographic, and contrast fluoroscopy assessment of the urinary tract. Afterward, unilateral laparoscopic ureteral stricture model was performed. Three weeks later, the animals underwent laser endoureterotomy and were randomly assigned to Group-I, in which a double-pigtail stent was placed for 6 weeks, or Group-II, in which a BraidStent®-H was placed. Follow-up was carried out by ultrasonography, contrast fluoroscopy, ureteroscopy, urinalysis and bacteriuria assessment at 3, 6, 12 and 5 months. Finally, a pathological study of the urinary system was performed.

Results

There were no animals in Group-II with vesicoureteral reflux, with significance at 6 weeks with Group-I. Distal ureteral peristalsis was maintained in 50-75% in Group-II at 1-6 weeks. The 91.7% of stents in Group-II were degraded between 3-6 weeks, without obstructive fragments. Bacteriuria in Group II was 33.3-50% at 3 and 6 weeks. The global success rate by groups was 91.6% and 87.5% in groups I and II, respectively, with no statistical significance. Conclusions: BraidStent®-H has been shown to be as efficacious as current ureteral stents in the treatment of benign ureteral strictures following laser endoureterotomy. In addition, it reduces the morbidity associated with current stents and has a homogeneous and predictable degradation rate of about 6 weeks, with no obstructive fragments. Future studies are required to improve the antibacterial coating to reduce BraidStent®-H contamination in view of the results obtained with the heparin coating.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。