Simultaneous detection of EGFR amplification and EGFRvIII variant using digital PCR-based method in glioblastoma

采用基于数字 PCR 的方法同时检测胶质母细胞瘤中的 EGFR 扩增和 EGFRvIII 变异

阅读:14
作者:Maxime Fontanilles, Florent Marguet, Philippe Ruminy, Carole Basset, Adrien Noel, Ludivine Beaussire, Mathieu Viennot, Pierre-Julien Viailly, Kevin Cassinari, Pascal Chambon, Doriane Richard, Cristina Alexandru, Isabelle Tennevet, Olivier Langlois, Frédéric Di Fiore, Annie Laquerrière, Florian Clato

Abstract

Epidermal growth factor receptor (EGFR) amplification and EGFR variant III (EGFRvIII, deletion of exons 2-7) are of clinical interest for glioblastoma. The aim was to develop a digital PCR (dPCR)-based method using locked nucleic acid (LNA)-based hydrolysis probes, allowing the simultaneous detection of the EGFR amplification and EGFRvIII variant. Sixty-two patients were included. An exploratory cohort (n = 19) was used to develop the dPCR assay using three selected amplicons within the EGFR gene, targeting intron 1 (EGFR1), junction of exon 3 and intron 3 (EGFR2) and intron 22 (EGFR3). The copy number of EGFR was estimated by the relative quantification of EGFR1, EGFR2 and EGFR3 amplicon droplets compared to the droplets of a reference gene. EGFRvIII was identified by comparing the copy number of the EGFR2 amplicon to either the EGFR1 or EGFR3 amplicon. dPCR results were compared to fluorescence in situ hybridization (FISH) and next-generation sequencing for amplification; and to RT-PCR-based method for EGFRvIII. The dPCR assay was then tested in a validation cohort (n = 43). A total of 8/19 EGFR-amplified and 5/19 EGFRvIII-positive tumors were identified in the exploratory cohort. Compared to FISH, the EGFR3 dPCR assay detected all EGFR-amplified tumors (8/8, 100%) and had the highest concordance with the copy number estimation by NGS. The concordance between RT-PCR and dPCR was also 100% for detecting EGFRvIII using an absolute difference of 10.8 for the copy number between EGFR2 and EGFR3 probes. In the validation cohort, the sensitivity and specificity of dPCR using EGFR3 probes were 100% for the EGFR amplification detection compared to FISH (19/19). EGFRvIII was detected by dPCR in 8 EGFR-amplified patients and confirmed by RT-PCR. Compared to FISH, the EGFR2/EGFR3 dPCR assay was estimated with a one-half cost value. These results highlight that dPCR allowed the simultaneous detection of EGFR amplification and EGFRvIII for glioblastoma.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。