OBJECTIVE: To establish optimised diffusion weightings ('b-values') for acquisition of whole-body diffusion-weighted MRI (WB-DWI) for estimation of the apparent diffusion coefficient (ADC) in patients with metastatic melanoma (MM). Existing recommendations for WB-DWI have not been optimised for the tumour properties in MM; therefore, evaluation of acquisition parameters is essential before embarking on larger studies. METHODS: Retrospective clinical data and phantom experiments were used. Clinical data comprised 125 lesions from 14 examinations in 11 patients with multifocal MM, imaged before and/or after treatment with immunotherapy at a single institution. ADC estimates from these data were applied to a model to estimate the optimum b-value. A large non-diffusing phantom was used to assess eddy current-induced geometric distortion. RESULTS: Considering all tumour sites from pre- and post-treatment examinations together, metastases exhibited a large range of mean ADC values, [0.67-1.49] à 10(-3) mm(2)/s, and the optimum high b-value (b(high)) for ADC estimation was 1100 (10th-90th percentile: 740-1790) s/mm(2). At higher b-values, geometric distortion increased, and longer echo times were required, leading to reduced signal. CONCLUSIONS: Theoretical optimisation gave an optimum b(high) of 1100 (10th-90th percentile: 740-1790) s/mm(2) for ADC estimation in MM, with the large range of optimum b-values reflecting the wide range of ADC values in these tumours. Geometric distortion and minimum echo time increase at higher b-values and are not included in the theoretical optimisation; b(high) in the range 750-1100 s/mm(2) should be adopted to maintain acceptable image quality but performance should be evaluated for a specific scanner. KEY POINTS: ⢠Theoretical optimisation gave an optimum high b-value of 1100 (10th-90th percentile: 740-1790) s/mm(2) for ADC estimation in metastatic melanoma. ⢠Considering geometric distortion and minimum echo time (TE), a b-value in the range 750-1100 s/mm(2) is recommended. ⢠Sites should evaluate the performance of specific scanners to assess the effect of geometric distortion and minimum TE.
Optimisation of b-values for the accurate estimation of the apparent diffusion coefficient (ADC) in whole-body diffusion-weighted MRI in patients with metastatic melanoma.
阅读:5
作者:Knill Annemarie K, Blackledge Matthew D, Curcean Andra, Larkin James, Turajlic Samra, Riddell Angela, Koh Dow Mu, Messiou Christina, Winfield Jessica M
| 期刊: | European Radiology | 影响因子: | 4.700 |
| 时间: | 2023 | 起止号: | 2023 Feb;33(2):863-871 |
| doi: | 10.1007/s00330-022-09088-5 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。
