Setup uncertainties and the optimal imaging schedule in the prone position whole breast radiotherapy.

阅读:3
作者:Yao Shengyu, Zhang Yin, Nie Ke, Liu Bo, Haffty Bruce G, Ohri Nisha, Yue Ning J
BACKGROUND: To investigate the setup uncertainties and to establish an optimal imaging schedule for the prone-positioned whole breast radiotherapy. METHODS: Twenty prone-positioned breast patients treated with tangential fields from 2015 to 2017 were retrospectively enrolled in this study. The prescription dose for the whole breast treatment was 266 cGy × 16 for all of the patients and the treatments were delivered with the SSD setup technique. At every fraction of treatment, patient was firstly set up based on the body localization tattoos. MV portal imaging was then taken to confirm the setup; if discrepancy (> 3 mm) was found between the portal images and corresponding plan images, the patient positioning was adjusted accordingly with couch movement. Based on the information acquired from the daily tattoo and portal imaging setup, three sets of data, named as weekly imaging guidance (WIG), no daily imaging guidance (NIG), and initial 3 days then weekly imaging guidance (3 + WIG) were sampled, constructed, and analyzed in reference to the benchmark of the daily imaging guidance (DIG). We compared the setup uncertainties, target coverage (D(95), D(max)), V(5) of the ipsilateral lung, the mean dose of heart, the mean and max dose of the left-anterior-descending coronary artery (LAD) among the 4 imaging guidance (IG) schedules. RESULTS: Relative to the daily imaging guidance (IG) benchmark, the NIG schedule led to the largest residual setup uncertainties; the uncertainties were similar for the WIG and 3 + WIG schedules. Little variations were observed for D(95) of the target among NIG, DIG and WIG. The target D(max) also exhibited little changes among all the IG schedules. While V(5) of the ipsilateral lung changed very little among all 4 schedules, the percent change of the mean heart dose was more pronounced; but its absolute values were still within the tolerance. However, for the left-sided breast patients, the LAD dose could be significantly impacted by the imaging schedules and could potentially exceed its tolerance criteria in some patients if NIG, WIG and 3 + WIG schedules were used. CONCLUSIONS: For left-side whole breast treatment in the prone position using the SSD treatment technique, the daily imaging guidance can ensure dosimetric coverage of the target as well as preventing critical organs, especially LAD, from receiving unacceptable levels of dose. For right-sided whole breast treatment in the prone position, the weekly imaging setup guidance appears to be the optimal choice.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。