Deep learning super-resolution reconstruction for fast and high-quality cine cardiovascular magnetic resonance

用于快速高质量电影心血管磁共振的深度学习超分辨率重建

阅读:1

Abstract

OBJECTIVES: To compare standard-resolution balanced steady-state free precession (bSSFP) cine images with cine images acquired at low resolution but reconstructed with a deep learning (DL) super-resolution algorithm. MATERIALS AND METHODS: Cine cardiovascular magnetic resonance (CMR) datasets (short-axis and 4-chamber views) were prospectively acquired in healthy volunteers and patients at normal (cine(NR): 1.89 × 1.96 mm(2), reconstructed at 1.04 × 1.04 mm(2)) and at a low-resolution (2.98 × 3.00 mm(2), reconstructed at 1.04 × 1.04 mm(2)). Low-resolution images were reconstructed using compressed sensing DL denoising and resolution upscaling (cine(DL)). Left ventricular ejection fraction (LVEF), end-diastolic volume index (LVEDVi), and strain were assessed. Apparent signal-to-noise (aSNR) and contrast-to-noise ratios (aCNR) were calculated. Subjective image quality was assessed on a 5-point Likert scale. Student's paired t-test, Wilcoxon matched-pairs signed-rank-test, and intraclass correlation coefficient (ICC) were used for statistical analysis. RESULTS: Thirty participants were analyzed (37 ± 16 years; 20 healthy volunteers and 10 patients). Short-axis views whole-stack acquisition duration of cine(DL) was shorter than cine(NR) (57.5 ± 8.7 vs 98.7 ± 12.4 s; p < 0.0001). No differences were noted for: LVEF (59 ± 7 vs 59 ± 7%; ICC: 0.95 [95% confidence interval: 0.94, 0.99]; p = 0.17), LVEDVi (85.0 ± 13.5 vs 84.4 ± 13.7 mL/m(2); ICC: 0.99 [0.98, 0.99]; p = 0.12), longitudinal strain (-19.5 ± 4.3 vs -19.8 ± 3.9%; ICC: 0.94 [0.88, 0.97]; p = 0.52), short-axis aSNR (81 ± 49 vs 69 ± 38; p = 0.32), aCNR (53 ± 31 vs 45 ± 27; p = 0.33), or subjective image quality (5.0 [IQR 4.9, 5.0] vs 5.0 [IQR 4.7, 5.0]; p = 0.99). CONCLUSION: Deep-learning reconstruction of cine images acquired at a lower spatial resolution led to a decrease in acquisition times of 42% with shorter breath-holds without affecting volumetric results or image quality. KEY POINTS: Question Cine CMR acquisitions are time-intensive and vulnerable to artifacts. Findings Low-resolution upscaled reconstructions using DL super-resolution decreased acquisition times by 35-42% without a significant difference in volumetric results or subjective image quality. Clinical relevance DL super-resolution reconstructions of bSSFP cine images acquired at a lower spatial resolution reduce acquisition times while preserving diagnostic accuracy, improving the clinical feasibility of cine imaging by decreasing breath hold duration.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。