Transpulmonary thermodilution detects rapid and reversible increases in lung water induced by positive end-expiratory pressure in acute respiratory distress syndrome

经肺热稀释法可检测急性呼吸窘迫综合征中由呼气末正压引起的肺水快速且可逆的增加。

阅读:1

Abstract

PURPOSE: It has been suggested that, by recruiting lung regions and enlarging the distribution volume of the cold indicator, increasing the positive end-expiratory pressure (PEEP) may lead to an artefactual overestimation of extravascular lung water (EVLW) by transpulmonary thermodilution (TPTD). METHODS: In 60 ARDS patients, we measured EVLW (PiCCO2 device) at a PEEP level set to reach a plateau pressure of 30 cmH(2)O (HighPEEP(start)) and 15 and 45 min after decreasing PEEP to 5 cmH(2)O (LowPEEP(15') and LowPEEP(45'), respectively). Then, we increased PEEP back to the baseline level (HighPEEP(end)). Between HighPEEP(start) and LowPEEP(15'), we estimated the degree of lung derecruitment either by measuring changes in the compliance of the respiratory system (Crs) in the whole population, or by measuring the lung derecruited volume in 30 patients. We defined patients with a large derecruitment from the other ones as patients in whom the Crs changes and the measured derecruited volume were larger than the median of these variables observed in the whole population. RESULTS: Reducing PEEP from HighPEEP(start) (14 ± 2 cmH(2)O) to LowPEEP(15') significantly decreased EVLW from 20 ± 4 to 18 ± 4 mL/kg, central venous pressure (CVP) from 15 ± 4 to 12 ± 4 mmHg, the arterial oxygen tension over inspired oxygen fraction (PaO(2)/FiO(2)) ratio from 184 ± 76 to 150 ± 69 mmHg and lung volume by 144 [68-420] mL. The EVLW decrease was similar in "large derecruiters" and the other patients. When PEEP was re-increased to HighPEEP(end), CVP, PaO(2)/FiO(2) and EVLW significantly re-increased. At linear mixed effect model, EVLW changes were significantly determined only by changes in PEEP and CVP (p < 0.001 and p = 0.03, respectively, n = 60). When the same analysis was performed by estimating recruitment according to lung volume changes (n = 30), CVP remained significantly associated to the changes in EVLW (p < 0.001). CONCLUSIONS: In ARDS patients, changing the PEEP level induced parallel, small and reversible changes in EVLW. These changes were not due to an artefact of the TPTD technique and were likely due to the PEEP-induced changes in CVP, which is the backward pressure of the lung lymphatic drainage. Trial registration ID RCB: 2015-A01654-45. Registered 23 October 2015.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。