Comparing intra-abdominal pressures in different body positions via a urinary catheter and nasogastric tube: a pilot study

通过导尿管和鼻胃管比较不同体位下的腹内压:一项初步研究

阅读:1

Abstract

OBJECTIVES: Intra-abdominal pressure (IAP) is most commonly measured via the bladder with the patient in the supine position. In the ICU, patients are nursed with the head of the bed elevated at 30° (HOB30) to reduce the risk of ventilator-associated pneumonia. This study investigated whether gastric pressure at HOB30 can be used as a surrogate measure of IAP via the bladder in the supine position. METHODS: A prospective observational study was conducted in a single-centre intensive care unit. A total of 20 patients were included. IAP was recorded simultaneously via the bladder catheter (bladder pressure, IBP) and via nasogastric tube (gastric pressures, IGP) in the supine and HOB30 position. Each patient had three sets of IAP measurements performed at least 4 h apart. RESULTS: In the supine position, mean IBP was 12.3 ± 4.5 mmHg compared to IGP of 11.8 ± 4.7 mmHg. The bias between the two groups was 0.5 and precision of 3.7 (LA, -6.8 to 7.5 mmHg). At 30 degrees, mean IBP was 15.8 ± 4.9 mmHg compared to IGP of 13.1 ± 6.1 mmHg. The bias between both groups was 2.7 with a precision of 5.5 (LA, -8.0 to 13.5). Comparing IBP in the supine position with IGP at 30° showed a bias of -0.8 and precision of 5.6 (LA, -10.1 to 11.6 mmHg). CONCLUSION: IAP measured via a nasogastric tube was less influenced by changing the body position from supine to HOB30 than was bladder pressure.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。