Intra-abdominal pressure measurement using the FoleyManometer does not increase the risk for urinary tract infection in critically ill patients

使用弗雷氏腹腔压力计测量腹内压不会增加危重患者发生尿路感染的风险。

阅读:1

Abstract

OBJECTIVE: The aim of this study was to determine whether intra-abdominal pressure (IAP) monitoring using the FoleyManometer (Holtech Medical, Charlottenlund, Denmark) increases the risk of urinary tract infection (UTI). DESIGN: A retrospective database review was conducted. SETTING: The study was conducted in the 12-bed medical intensive care unit of ZNA Stuivenberg Hospital (Antwerp, Belgium), a tertiary hospital. PATIENTS: There were 5,890 patients admitted to the medical intensive care unit of which 1,097 patients underwent intrabladder pressure (IBP) monitoring as estimate for IAP. INTERVENTIONS: Crude and adjusted UTI rates were compared among patients undergoing IAP measurements with three different intrabladder methods: a modified homemade technique, a FoleyManometer with 35 ml reservoir, and a FoleyManometer low volume (FoleyManometerLV) with less than 10 ml priming volume. MEASUREMENTS AND RESULTS: Four consecutive time periods of 24 months were defined and compared with regard to IAP measurement: period 1 (2000-2001), during which IAP monitoring was not used routinely (which serves as a control group), was compared with period 2 (2002-2003), using a modified homemade technique; period 3 (2004-2005), introducing the FoleyManometer; and finally period 4 (2006-2007), in which the FoleyManometerLV was introduced. The incidence of IBP measurements increased from 1.4% in period 1 to 45.4% in period 4 (p < 0.001). At the same time, the Simplified Acute Physiology Score (version 2) (SAPS-II) increased significantly from 24.4 ± 21.5 to 34.9 ± 18.7 (p < 0.001) together with the percentage of ventilated patients from 18.6% to 40.7% (p < 0.001). In total, 1,097 patients had IAP measurements via the bladder. The UTI rates were adjusted for disease severity by multiplying each crude rate with the ratio of control versus study patient SAPS-II probability of mortality. Crude and adjusted UTI rates per 1,000 catheter days (CD) were on average 16.1 and 12.8/1,000 CD, respectively, and were not significantly different between the four time periods. CONCLUSIONS: Intrabladder pressure monitoring as estimate for IAP either via a closed transducer technique or the closed FoleyManometer technique seems safe and does not alter the risk of UTI in critically ill patients.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。