A multicenter analytical performance evaluation of a multiplexed immunoarray for the simultaneous measurement of biomarkers of micronutrient deficiency, inflammation and malarial antigenemia

一项多中心分析性能评估,旨在评估一种用于同时测量微量营养素缺乏、炎症和疟疾抗原血症生物标志物的多重免疫芯片的性能。

阅读:2

Abstract

A lack of comparative data across laboratories is often a barrier to the uptake and adoption of new technologies. Furthermore, data generated by different immunoassay methods may be incomparable due to a lack of harmonization. In this multicenter study, we describe validation experiments conducted in a single lab and cross-lab comparisons of assay results to assess the performance characteristics of the Q-plex™ 7-plex Human Micronutrient Array (7-plex), an immunoassay that simultaneously quantifies seven biomarkers associated with micronutrient (MN) deficiencies, inflammation and malarial antigenemia using plasma or serum; alpha-1-acid glycoprotein, C-reactive protein, ferritin, histidine-rich protein 2, retinol binding protein 4, soluble transferrin receptor, and thyroglobulin. Validations included repeated testing (n = 20 separately prepared experiments on 10 assay plates) in a single lab to assess precision and linearity. Seven independent laboratories tested 76 identical heparin plasma samples collected from a cohort of pregnant women in Niger using the same 7-plex assay to assess differences in results across laboratories. In the analytical validation experiments, intra- and inter-assay coefficients of variation were acceptable at <6% and <15% respectively and assay linearity was 96% to 99% with the exception of ferritin, which had marginal performance in some tests. Cross-laboratory comparisons showed generally good agreement between laboratories in all analyte results for the panel of 76 plasma specimens, with Lin's concordance correlation coefficient values averaging ≥0.8 for all analytes. Excluding plates that would fail routine quality control (QC) standards, the inter-assay variation was acceptable for all analytes except sTfR, which had an average inter-assay coefficient of variation of ≥20%. This initial cross-laboratory study demonstrates that the 7-plex test protocol can be implemented by users with some experience in immunoassay methods, but familiarity with the multiplexed protocol was not essential.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。