Evaluation of Antibacterial Activity of Three Quaternary Ammonium Disinfectants on Different Germs Isolated from the Hospital Environment

评价三种季铵盐消毒剂对从医院环境中分离的不同细菌的抗菌活性

阅读:1

Abstract

BACKGROUND: The microbiological risk of the hospital environment, including inert surfaces, medical devices, and equipment, represents a real problem. OBJECTIVE: This study is aimed at demonstrating and assessing the antibacterial activity of three synthetic disinfectants classified as quaternary ammoniums on different bacterial strains (Gram-negative and Gram-positive like Escherichia coli, Klebsiella pneumoniae, Enterobacter cloacae, Pseudomonas aeruginosa, Acinetobacter baumannii, and Staphylococcus aureus) isolated from the hospital environment. The reference strains included Escherichia coli ATCC 25922, Staphylococcus aureus ATCC 29213, and Pseudomonas aeruginosa ATCC 27853 used as negative control strains. METHOD: Three quaternary ammonium disinfectants were tested: DDN9® (0.5%) which contains didecylmethylpolyoxyethylammonium propionate as an active substance, spray (0.4%) containing quaternary ammonium compounds, and Phagosurf ND® (0.4%) with didecyldimethylammonium chloride. Their effect was evaluated using the disk diffusion technique and the broth dilution methods, allowing the Minimum Inhibitory Concentration (MIC) and then the Minimum Bactericidal Concentration (MBC). RESULT: Only the growth of Gram-positive bacteria and some strains of Gram-negative bacteria were inhibited by the three synthetic disinfectants. NDD9® demonstrated an antibacterial effect only against the Gram-positive strains (S. aureus and S. aureus ATCC 29213) with a MIC of 0.25 mg/ml. The disinfectant spray showed effect against all four strains including E. coli (9), S. aureus, E. coli ATCC 25922, and P. aeruginosa ATCC 27853 with an inhibitory concentration of 4 mg/ml, while the growth of S. aureus ATCC 29213 was inhibited at 2 mg/ml. The third disinfectant, Phagosurf ND®, inhibited only the growth of S. aureus ATCC 29213 at a MIC of 4 mg/ml. CONCLUSION: This study is the first here in Morocco to evaluate the bacterial activity of products intended for the control of the healthcare environment. The results obtained on the three disinfectants tested reveal an ineffectiveness against some isolated strains from the hospital environment.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。