T vector velocity: A new ECG biomarker for identifying drug effects on cardiac ventricular repolarization

T向量速度:一种用于识别药物对心室复极化影响的新型心电图生物标志物

阅读:1

Abstract

BACKGROUND: We present a new family of ECG biomarkers for assessing drug effects on ventricular repolarization. We show that drugs blocking inward (depolarizing) ion currents cause a relative increase of the T vector velocity (TVV) and accelerate repolarization, while drugs blocking outward ion currents cause a relative decrease of the TVV and delay repolarization. The results suggest a link between the TVV and the instantaneous change of the cellular action potentials that may contribute to bridge the gap between the surface ECG and myocardial cellular processes. METHODS: We measure TVV as the time required to reach X% of the total Trajectory length of the T vector loop, denoted as TrX. Applied to data from two FDA funded studies (22+22 subjects, 5232+4208 ECGs) which target ECG effects of various ion-channel blocking drugs, the TrX effect profiles indicate increasingly delayed electrical activity over the entire repolarization process for drugs solely reducing outward potassium current (dofetilide, moxifloxacin). For drugs eliciting block of the inward sodium or calcium currents (mexiletine, lidocaine), the TrX effect profiles were consistent with accelerated electrical activity in the initial repolarization phase. For multichannel blocking drugs (ranolazine) or drug combinations blocking multiple ion currents (dofetilide + mexiletine, dofetilide + lidocaine), the overall TrX effect profiles indicate a superposition of the individual TrX effect profiles. RESULTS: The parameter Tr40c differentiates pure potassium channel blocking drugs from multichannel blocking drugs with an area under the ROC curve (AUC) of 0.90, CI = [0.88 to 0.92]. This is significantly better than the performance of J-Tpeakc (0.81, CI = [0.78 to 0.84]) identified as the best parameter in the second FDA study. Combining the ten parameters Tr10c to Tr100c in a logistic regression model further improved the AUC to 0.94, CI = [0.92 to 0.96]. CONCLUSIONS: TVV analysis substantially improves assessment of drug effects on cardiac repolarization, providing a plausible and improved mechanistic link between drug effects on ionic currents and overall ventricular repolarization reflected in the body surface ECG. TVV contributes to an enhanced appraisal of the proarrhythmic risk of drugs beyond QTc prolongation and J-Tpeakc.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。