A Modified Method for the Quantification of Immune Checkpoint Ligands on Exosomes from Human Serum using Flow Cytometry

利用流式细胞术定量人血清外泌体上免疫检查点配体的改进方法

阅读:1
作者:Alan Guillermo Alejandre Gonzalez ,Pablo Cesar Ortiz-Lazareno ,Fabiola Solorzano-Ibarra ,Jorge Gutierrez-Franco ,Martha Cecilia Tellez-Bañuelos ,Miriam Ruth Bueno-Topete ,Susana Del Toro-Arreola ,Jesse Haramati

Abstract

Objectives: Exosomes are the smallest of the extracellular vesicles and can contain a variety of different cargos, including nucleic acids, lipids, and proteins. Ultracentrifugation followed by electron microscopy has historically been used for the isolation and visualization of exosomes; Western blot and ELISA have also been used, but these techniques are only semiquantitative and are unable to distinguish different exosome markers in the same sample. To resolve some of these issues, we propose a modification of a bead-based flow cytometry method. Methods: Peripheral blood serum was mixed with a commercial exosome separation reagent and incubated for 30 min at 4°, centrifuged, exosome pellet was isolated and resuspended in PBS. Exosomes were then added to magnetic beads, incubated 18 h, then incubated with exosome-specific antibodies for 1 h. The resulting bead:exosome complexes were centrifuged and then washed, then washed again using a magnetic separator, resuspended in PBS, and analyzed via flow cytometry. Results: Using commercial magnetic beads bound with anti-CD63, our protocol modifies starting conditions, washing steps, and magnetic separation and uses the FSC and SSC determination of the flow cytometer to result in increased yield and identification of the exosome populations of interest. Our modified protocol increased the yield of specific populations approximately 10-fold. Conclusion: The new protocol was used to identify exosomes positive for 2 immune checkpoint ligands in serum-derived exosomes from cervical cancer patients. We suspect that this protocol can also be used for the identification of other exosome proteins since we also quantified the exosome membrane-enriched tetraspanins CD9 and CD81. Identification of proteins rarely expressed in exosomes is complicated in this technique as serum is an inherently dirty source of exosomes, and great care must be taken in the washing and gating of the exosome:bead populations.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。