Repeatability and reproducibility of cerebral (23)Na imaging in healthy subjects

健康受试者脑部(23)Na成像的重复性和再现性

阅读:1

Abstract

BACKGROUND: Initial reports of (23)Na magnetic resonance imaging (MRI) date back to the 1970s. However, methodological challenges of the technique hampered its widespread adoption for many years. Recent technical developments have overcome some of these limitations and have led to more optimal conditions for (23)Na-MR imaging. In order to serve as a reliable tool for the assessment of clinical stroke or brain tumor patients, we investigated the repeatability and reproducibility of cerebral sodium ((23)Na) imaging in healthy subjects. METHODS: In this prospective, IRB approved study 12 consecutive healthy volunteers (8 female, age 31 ± 8.3) underwent three cerebral (23)Na-MRI examinations at 3.0 T (TimTrio, Siemens Healthineers) distributed between two separate visits with an 8 day interval. For each scan a T1w MP-RAGE sequence for anatomical referencing and a 3D-density-adapted, radial GRE-sequence for (23)Na-imaging were acquired using a dual-tuned ((23)Na/(1)H) head-coil. On 1 day, these scans were repeated consecutively; on the other day, the scans were performed once. (23)Na-sequences were reconstructed according to the MP-RAGE sequence, allowing direct cross-referencing of ROIs. Circular ROIs were placed in predetermined anatomic regions: gray and white matter (GM, WM), head of the caudate nucleus (HCN), pons, and cerebellum. External (23)Na-reference phantoms were used to calculate the tissue sodium content. RESULTS: Excellent correlation was found between repeated measurements on the same day (r(2) = 0.94), as well as on a different day (r(2) = 0.86). No significant differences were found based on laterality other than in the HCN (63.1 vs. 58.7 mmol/kg WW on the right (p = 0.01)). Pronounced inter-individual differences were identified in all anatomic regions. Moderate to good correlation (0.310 to 0.701) was found between the readers. CONCLUSION: Our study has shown that intra-individual (23)Na-concentrations in healthy subjects do not significantly differ after repeated scans on the same day and a pre-set time interval. This confirms the repeatability and reproducibility of cerebral (23)Na-imaging. However, with manual ROI placement in predetermined anatomic landmarks, fluctuations in (23)Na-concentrations can be observed.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。