Abstract

OBJECTIVE: To re-evaluate gonad shielding in paediatric pelvic radiography in terms of attainable radiation risk reduction and associated loss of diagnostic information. METHODS: A study on patient dose and the quality of gonad shielding was performed retrospectively using 500 pelvic radiographs of children from 0 to 15 years old. In a subsequent study, 195 radiographs without gonad shielding were included. Patient doses and detriment adjusted risks for heritable disease and cancer were calculated with and without gonad shielding. RESULTS: For girls, gonad shields were placed incorrectly in 91% of the radiographs; for boys, in 66%. Without gonad shielding, the hereditary detriment adjusted risk for girls ranged between 0.1 × 10(-6) and 1.3 × 10(-6) and for boys between 0.3 × 10(-6) and 3.9 × 10(-6), dependent on age. With shielding, the reduction in hereditary risk for girls was on average 6 ± 3% of the total risk of the radiograph, for boys 24 ± 6%. Without gonad shielding, the effective dose ranged from 0.008 to 0.098 mSv. CONCLUSIONS: With modern optimised X-ray systems, the reduction of the detriment adjusted risk by gonad shielding is negligibly small. Given the potential consequences of loss of diagnostic information, of retakes, and of shielding of automatic exposure-control chambers, gonad shielding might better be discontinued.