Crime Light Imaging (CLI): A Novel Sensor for Stand-Off Detection and Localization of Forensic Traces

犯罪现场照明成像(CLI):一种用于远距离检测和定位法医痕迹的新型传感器

阅读:1

Abstract

Stand-off detection of latent traces avoids the scene alteration that might occur during close inspection by handheld forensic lights. Here, we describe a novel sensor, named Crime Light Imaging (CLI), designed to perform high-resolution photography of targets at a distance of 2-10 m and to visualize some common latent traces. CLI is based on four high-power illumination LEDs and one color CMOS camera with a motorized objective plus frontal filters; the LEDs and camera could be synchronized to obtain short-exposure images weakly dependent on the ambient light. The sensor is integrated into a motorized platform, providing the target scanning and necessary information for 3D scene reconstruction. The whole system is portable and equipped with a user-friendly interface. The preliminary tests of CLI on fingerprints at distance of 7 m showed an excellent image resolution and drastic contrast enhancement under green LED light. At the same distance, a small (1 µL) blood droplet on black tissue was captured by CLI under NIR LED, while a trace from 15 µL semen on white cotton became visible under UV LED illumination. These results represent the first demonstration of true stand-off photography of latent traces, thus opening the way for a completely new approach in crime scene forensic examination.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。